Sunday, 24 June 2012

Pelton wheel / Pelton turbine / Hydro-power (3D animation)

Posted on 17:31 by Unknown



The Pelton turbine is an impulse turbine that extracts energy from the impulse of moving water and is the preferred turbine for hydro-power.
Read More
Posted in Turbine | No comments

Wednesday, 17 February 2010

Francis Turbine

Posted on 02:23 by Unknown
Francis Turbine



Francis Turbine Blade



The Francis turbine is a type of water turbine that was developed by James B. Francis. It is an inward flow reaction turbine that combines radial and axial flow concepts. Francis turbines are the most common water turbine in use today. They operate in a head range of ten meters to several hundred meters and are primarily used for electrical power production.



Theory of Operation

The Francis turbine is a reaction turbine, which means that the working fluid changes pressure as it moves through the turbine, giving up its energy. A casement is needed to contain the water flow. The turbine is located between the high pressure water source and the low pressure water exit, usually at the base of a dam.The inlet is spiral shaped. Guide vanes direct the water tangentially to the turbine wheel, known as a runner. This radial flow acts on the runner's vanes, causing the runner to spin. The guide vanes (or wicket gate) may be adjustable to allow efficient turbine operation for a range of water flow conditions. As the water moves through the runner its spinning radius decreases, further acting on the runner. For an analogy, imagine swinging a ball on a string around in a circle; if the string is pulled short, the ball spins faster due to the conservation of angular momentum. This property, in addition to the water's pressure, helps Francis and other inward-flow turbines harness water energy efficiently.



Application



Francis turbines may be designed for a wide range of heads and flows. This, along with their high efficiency, has made them the most widely used turbine in the world. Francis type units cover a head range from 20 meters to 700 meters, and their output power varies from just a few kilowatts up to one gigawatt. Large Francis turbines are individually designed for each site to operate at the highest possible efficiency, typically over 90%. In addition to electrical production, they may also be used for pumped storage; where a reservoir is filled by the turbine (acting as a pump) during low power demand, and then reversed and used to generate power during peak demand.





Read More
Posted in Hydrolectricity, Turbine | No comments

Thursday, 20 November 2008

Levelflex M FMP45 - ABKASJB23A2A To Be Installed at HP Heater No.8

Posted on 07:51 by Unknown
Old Foxboro Level Transmitter

Levelflex M FMP45 - ABKASJB23A2A To Be Installed at Hp Heater No.8

Levelflex M FMP45 - ABKASJB23A2A

Level measurement, guided radar.
High pressure/high temperature.
Application: mainly liquids.
Ideal to measure in bypass/chamber.
Setup-/diagnostic software included.
Factory precalibrated.
Reliable measuring:
:: in case of moved surface + foam
:: for changing medias
SIL declaration of conformity
A Approval: Non-hazardous area
B Process Temperature: -200...+400oC/-328...+752oF (HT)
K Probe: 1,200mm,rod 16mm, 316L
ASJ Process Connection: 3" 300/600lbs RF, 316/316L flange ANSI B16.5
B Power Supply; Output: 2-wire; 4-20mA SIL HART
2 Operation:4-line display VU331,Envelope curve display on site
3 Type of Probe: Remote, cable 3m,top entry
A Housing: F12 Alu, coated IP68 NEMA6P
2 cable Entry: Gland M20 (EEx d > thread M20)
A Additional Option: Basic version


Hardware Extern, Miscellaneous


To dismantle existing level transmitter and install new E+H High
Temperature Level Transmitter completes the following breakdown:-
a) To supply 3” spiral wound gasket #600
Qty – 1 set
b) To fabricate and supply & install stand for housing bracket
Qty – 1 set
c) To supply & install stud bolt M18x140mm SS304 c/w 2 nuts
Qty – 8 pcs
d) To fabricate, supply & install cable tray
Qty – 1 set
e) Man power, tools & equipment – 1 lot
f) Mobilize & Demobilize – 1 lot


Hardware Extern, Miscellaneous
1. To supply and install Flange Adaptor (4 holes to 8 holes)
2. ** Only apply for those chambers with 4 holes flange.

The work will be carry out by Endress Hauser Vendor by next week.
Read More
Posted in Transmitter, Turbine | No comments

Thursday, 18 September 2008

H2 Purity Gas Analyzer to be Purchase

Posted on 18:16 by Unknown

Specifications of spare parts for ABB Hydrogen Purity System with redundancy:

P/N : 6548-001

Manufacturer : ABB Automation, UK

Replacement Hydrogen Purity and Purge Gas katharometer with redundancy,

calibrated for 3 ranges of:

85 – 100% H2 in Air,

0 – 100% Air in CO2 and

0 – 100% H2 in CO2

Output : 0 – 10mV

Power Supply : 350mA

Zero Gas : 85% H2 in 15% Air

Note : Replacement for Serial No G846802

P/N : 4234-500

Manufacturer : ABB Automation, UK

Replacement Hydrogen Purity Power Supply Unit

Output : 350mA

Power Supply : 240Vac 50Hz

Note : Replacement for obsolete model with Serial No 004234000/02

Related articles:

- ABB H2 Panel Mounted Transmitter

- Hydrogen, H2 Gas Purity System

Read More
Posted in Analyser, Turbine | No comments

Wednesday, 10 September 2008

Row of Turbine or Generator

Posted on 00:53 by Unknown
Row of Turbine at in Turbine Hall Power Station

Maybe the pic (turbine) at the back of this unit not so clear... Sorry!
Read More
Posted in Turbine | No comments

Sunday, 31 August 2008

ABB Advant Controller 31 Analog I/O Card Failure

Posted on 03:01 by Unknown
ABB Advant Controller 31 Analog I/O 07AC91 Card

ABB Advant Controller 31 Analog I/O Card failure and effect all the Generator System. Currently problem solved by replace the faulty module 07AC91 and unit returned back in good condition.


Read More
Posted in PLC, Turbine | No comments

Thursday, 28 August 2008

Turbine Drain Sump Pit - Upgrading Level Probe Switch to Ultrasonic Switch Type

Posted on 20:52 by Unknown
Project in Progress - Turbine Drain Sump Pit - Upgrading Level Probe Switch to Ultrasonic Switch Type

The previous level probe switch always giving fault signal and disturbs controlling of the water level in the system. The new type of Ultrasonic Model non-contact which expected to be more robust and reliable.

Specifications:

FDU91F-RN1A* PROSONIC S
FMU90-R11CA131AA1A* PROSONIC S

RSG30-A1A1AAA1* ECOGRAGH T

Now it is almost complete.



Read More
Posted in Switch, Turbine | No comments

Wednesday, 6 August 2008

Turbine Jurnal Bearing Thermocouple

Posted on 23:33 by Unknown
Turbine Thermocouple (Sensor)

Turbine Thermocouple (Socket)

Turbine Thermocouple (Overall)


1) Thermocouple for turbine journal bearing:

Model: T22
Type: T Duplex
Length: 1000mm
Accessories: Male and female connector, mounting spring and pin connector
Quantity: 10 pieces

2) Thermocouple for turbine thrust bearing:

Model: T22
Type: T Duplex
Length: 400mm
Accessories: Male and female connector, mounting spring and pin connector
Quantity: 10 pieces
Read More
Posted in Turbine | No comments

Tuesday, 1 July 2008

Special Tools for Turbine Work (TSE)

Posted on 08:58 by Unknown
Special Tools for Turbine Work (TSE)


Read More
Posted in Turbine | No comments

Sunday, 29 June 2008

Turbine Generator Speed Sensor - Radio Energie Type Y9-50

Posted on 20:51 by Unknown
Turbine Generator Speed Sensor

Radio Energie Type Y9-50 Specification

Turbine Generator Speed Sensor - Radio Energie Type Y9-50


Read More
Posted in Transducer, Turbine | No comments

Thursday, 26 June 2008

Turbine Speed Sensor Photo

Posted on 21:17 by Unknown
Turbine Speed Sensor Photo

Read More
Posted in Transducer, Turbine | No comments

Wednesday, 28 May 2008

Turbine Blade Looks Like When Casing Removed

Posted on 19:28 by Unknown
Turbine Blade
Read More
Posted in Turbine | No comments

Wednesday, 16 April 2008

GE Matrix Proximity Sensor or Probe Alternative of Bently Nevada Probe

Posted on 09:30 by Unknown
Proximity Probe

ITEM : REVERSE MOUNT PROXIMITY PROBE
MODEL : MX330105-02-12-10-02-00
CASE THREAD : 3/8” – 24
UNTHREADED
LENGTH : 0.2 IN
PROBE LENGTH : 1.0 MTR
QUANTITY : 1 UNIT

This is alternative vibration sensor probe instead of Bently Nevada vibration sensor.


Read More
Posted in Transducer, Turbine | No comments

Wednesday, 12 March 2008

ABB Hydrogen Purity Gas Analyzer

Posted on 04:52 by Unknown
This is the link which I have mentioned related to Hydrogen Purity Gas Analyzer. Currently we are going to purchase some spares of it. Here is the lists;

1) Valve Metering
2) Power Supply Unit
3) Flow Meter
4) Ring Seal Coupling
5) Seal Top Drying Chamber
6) Gauze Drying Chamber
7) Zener Diode MTL70SS
8) Safety Barrier MTL77SS
9) Indicator Display H2/Air
10) Khatarometer Unit

I am not so sure about all these listing but I got these from the ABB's guy. Therefore I need to check details each of the instrumentation parts.

Read More
Posted in Package Equipment, Turbine | No comments

Wednesday, 20 February 2008

Turbine Function Block Generally

Posted on 08:15 by Unknown
This is another turbine function block which also contributed by my colleague as in my previous post.

Hopefully you can learn something on this big picture generally either on the turbine side or the boiler side. Happy learning!

Read More
Posted in Turbine | No comments

Tuesday, 5 February 2008

New Pressure Gauge to be Fitted at The Condenser Inlet Pipe

Posted on 02:16 by Unknown
The reason to fit the pressure gauge is to investigate the Cooling Water Pump problem and condenser performance. On each inlet and outlet leg there are stubs fitted with isolating valves and blank flange. Isolate, remove flange and drill and thread to suit pressure gauges. (Note one inlet leg has no isolating valve) Suggest gauges have to be as fitted on CW discharges i.e. SS 150MM dia, range 0 to 6 bar. See attached Photos.


On the outlet sides propose to fit gauges at lower level to make reading easier by piping impulse line down to suitable mounting location.

Read More
Posted in Gauge, Turbine | No comments

Friday, 1 February 2008

Unit No.1 High Pressure Heater No.6, 7 and 8 Emergency Control Valve Not Fully Shut

Posted on 03:11 by Unknown
HP HTR 8 level transmitter showing very low reading. Check at local gauge glass found actual level low. Check at the emergency control valve found, High Pressure Heater No.7 and No.8 valve position not fully shut and causing the HP HTR level drain to the flash box. DCS command to the control valve already fully shut. Suspect not enough air pressure to close the control valve (air to close).

After doing some checking, not enough air pressure to close the control valve from the volume booster. The function of volume booster is to boost big volume air to the valve diaphragm either fast closing or fast opening. Servicing done for all volume booster HP Heater and reading back to normal operation.

Checking at the store found that the stock level for this volume booster is also low and need to raise new purchase request. I enclose here the photo and the specification for you to review.


Volume
Booster
B
lackborough Control Valve
Model No : 25
SWP : 150 Psig
Pipe Conns : ¼ ” NPT

Read More
Posted in Turbine, Valve and Fitting | No comments

Wednesday, 30 January 2008

Introduction to Generator Hydrogen Gas Cooling System

Posted on 22:30 by Unknown
The gas unit for generator gas cooling comprises the components necessary to fill the generator with hydrogen, maintain it under pressure, check the gas purity and evacuate the generator. To prevent the formation of explosive gas mixtures, the air in the generator is expelled with CO2 prior to filling with H2.

Generator Hydrogen Gas Cooling Area

H2 gas is then pumped in, displacing the C02. When evacuating the generator, the order is reversed. The H2 is first expelled with CO2; afterwards the CO2 is expelled with compressed air (dry and oil-free).

Read More
Posted in Package Equipment, Turbine | No comments

What is A Steam Turbine?

Posted on 03:42 by Unknown
According to Wikepedia, steam turbine is a mechanical device that extracts heat energy from pressurize steam converts into the mechanical motion. 86% of electric generation in the world is using steam turbine. The steam turbine is a form of heat engine that derives much of its improvement in thermodynamic efficiency from the use of multiple stages in the expansion of the steam. A turbine contains dozens of louvers or angled blades mounted to a central shaft. The turbine output shaft is connected to a massive generator. The wheels and shaft begin to rotate at high speed when the dry super heated steam ported into the turbine. Meaning that its depend on heat source (boiler) to change the water into super heated steam. Manjung Power Plant is using burning coal in generate or produce power.
Read More
Posted in Turbine | No comments

Friday, 11 January 2008

Feed Water Tank Pressure Transmitter Bar Absolute

Posted on 02:17 by Unknown
This morning I got another email complaint on our instrumentation field device about Feedwater Tank Pressure Transmitter:

"I have been highlighting the Unit 1 Feedwater Tank Pressure Transmitters (01LAA11CP501A/B/C) since December 25th. The transmitters should read Bars Absolute but have been set to Bars Gauge. This means that the FWT Pressure Control operates at 2.7 barg (3.7 bar abs) instead of 1.7 barg (2.7 bar abs).

Please use this opportunity to correct this defect."

Actually it was already 5 years the pressure transmitter range mode in bar gauge for all three unit in our Coal Fired Power Plant and nobody highlighted this issue before. The original range is 0 to 15 bars gauge. Then when to change to absolute mode the range become -1.013 to 13.987 bars absolute. Job done and the reading left as 1.4 bars absolute as per mimic picture.

Read More
Posted in Transmitter, Turbine | No comments
Older Posts Home
Subscribe to: Posts (Atom)

Popular Posts

  • Foxboro Malaysia
    Yesterday, I posted about the Foxboro Absolute Pressure Transmitter . Then searching around the internet for their support and services in M...
  • Process pressure: Level and pressure measurements
    Measuring principle The pressure measuring cell converting the pressure into a signal which can be evaluated electrically is the heart of ...
  • The Global Positioning System (GPS)
    The Global Positioning System (GPS) is a space-based satellite navigation system that provides location and time information in all weathe...
  • AINOL Novo 7 Paladin
    One 7” Android 4.0 Tablet PC for RM399 instead of RM830 Two 7” Android 4.0 Tablet PCs for RM750 instead of RM1,660 (only RM375 per...
  • SJ Gelugor Power Station
    Stesen Janakuasa Gelugor is owned by TNB. 
  • CCI Sulzer Valve and Drag Control Valve
    Description: PV6 CCI Part Number: 103.215.282.001 Valve Serial Number: Valve Control Description: Seal Set PV6 CCI Part Number: 000.101.000....
  • DCS Vs SCADA
    DCS Vs SCADA DCS is process oriented: it looks at the controlled process (the chemical plant or whatever) as the centre of the universe, and...
  • Sultan Iskandar Power Station
    Sultan Iskandar Power Station or Pasir Gudang  Power Station is located at Pasir Gudang  Johor.  Type of Plant Thermal (2 ST), combined cycl...
  • Another Article Chernobyl Nuclear Power Plant Accident
    Picture: Chernobyl Power Plant Accident 1986 Date and Time of the Chernobyl Nuclear Power Plant Accident: The Chernobyl nuclear accide...
  • Offshore Oil Rigs Mechanical Completion & Commissioning, Including Construction
    Rationale for this Workshop 80% of the world's rig-building market is concentrated in Singapore . Consequently, shipyards in Sing...

Categories

  • Analyser
  • Bently Nevada
  • Boiler
  • Car
  • Card
  • Coal and Ash
  • DCS
  • Electrical
  • Electro Chlorination Plant
  • Equipment
  • Events
  • Gauge
  • General
  • Generator
  • Heat Exchanger
  • Hydraulic
  • Hydroelectricity
  • Hydrolectricity
  • IT
  • Microrec
  • Mill
  • Miscellaneous
  • Motor
  • Package Equipment
  • PLC
  • Power Plant
  • Pump
  • Pump House
  • Samsung
  • Solar Energy
  • Summary Report
  • Switch
  • System
  • Terminal Block
  • Test Equipment
  • Testing and Commissioning
  • Tools
  • Toyota
  • Transducer
  • Transmitter
  • Turbine
  • Valve and Fitting
  • Water Treatment Plant

Blog Archive

  • ▼  2014 (1)
    • ▼  January (1)
      • Sultan Iskandar Power Station
  • ►  2013 (41)
    • ►  December (9)
    • ►  November (20)
    • ►  September (2)
    • ►  July (1)
    • ►  June (2)
    • ►  May (2)
    • ►  April (1)
    • ►  February (2)
    • ►  January (2)
  • ►  2012 (39)
    • ►  December (2)
    • ►  November (1)
    • ►  October (9)
    • ►  September (1)
    • ►  July (1)
    • ►  June (3)
    • ►  April (5)
    • ►  March (9)
    • ►  February (5)
    • ►  January (3)
  • ►  2011 (82)
    • ►  December (2)
    • ►  November (2)
    • ►  October (4)
    • ►  September (1)
    • ►  August (7)
    • ►  July (11)
    • ►  June (12)
    • ►  May (6)
    • ►  April (13)
    • ►  March (14)
    • ►  February (7)
    • ►  January (3)
  • ►  2010 (66)
    • ►  December (16)
    • ►  November (17)
    • ►  October (8)
    • ►  September (19)
    • ►  August (2)
    • ►  July (1)
    • ►  May (1)
    • ►  February (2)
  • ►  2009 (33)
    • ►  November (6)
    • ►  October (7)
    • ►  September (6)
    • ►  August (1)
    • ►  June (3)
    • ►  May (1)
    • ►  March (2)
    • ►  February (4)
    • ►  January (3)
  • ►  2008 (182)
    • ►  December (1)
    • ►  November (2)
    • ►  October (7)
    • ►  September (11)
    • ►  August (26)
    • ►  July (6)
    • ►  June (7)
    • ►  May (9)
    • ►  April (21)
    • ►  March (43)
    • ►  February (22)
    • ►  January (27)
  • ►  2007 (2)
    • ►  December (1)
    • ►  November (1)
Powered by Blogger.

About Me

Unknown
View my complete profile