Unit No.3 Generator Stator Terminal Connection RTDs

Posted on 23:14 by Unknown
I got this email last week;

During the unit 3 trip on Saturday 29th December, it was noted that one of the Stator terminal connection point cooling water RTD devices 03MKA11CT611 went off scale, returning to normal about 5-6 hours later. Also, all of the time 03MKA11CT612 was sitting at zero. See attached trend.

While it might look as if the behavior of CT611 is genuine (not fluctuating or spiking), the Alstom Generator expert doesn’t believe that it can genuinely go that high after the generator tripped.

I took the opportunity myself to check the actual loop connections at the DCS and Generator (mA & RTD side of the transducers at the generator marshalling box) – all appear OK.

Could you ask someone to check the RTDs by direct measurement and the RTD-mA transducers by simulation, just to prove that they are working OK.

Also, if you get the chance, the RTD for Stator outlet winding temperature 03MKA11CT505 has been sat at 73-74 degC for the last few weeks without changing.

It would be preferable to do these checks before Unit 3 comes back on load, hopefully within the next day or 2.

Many thanks for your help in advance.

Here is our finding to that problem:

03MKA11CT505 ( Reading high at DCS )

Number cable

Number cable

Result ( Ω )

1

3

113.9

1

2

114

INPUT ( Ω ) OUTPUT ( mA )

mA

Reading at DCS

Reading at DCS

4

0

0

8

38

40

12

79

80

16

118

119

20

159

159

Remark Status

1. Check RTD resistant OK

2. Inject mA at DCS OK

3. Check mA at converter card reading 11.36mA converter card

after disconnect cable at converter card reading still 11.36mA faulty.

03MKA11CT611


Number cable

Number cable

Result ( Ω )

1

3

115.5

1

2

115.4



A

Reading at DCS

Reading at DCS

4

0.8

0.8

8

40.5

40.5

12

79.9

79.9

16

119.9

119.9

20

159.7

159.7

Remark Status

1. Check RTD resistant OK

2. Inject mA at DCS OK

3. Check mA at converter card reading 7.69mA OK


03MKA11CT612 ( Reading at DCS bad Q )

Number cable

Number cable

Result ( Ω )

1

3

113.9

1

2

113.8


A

Reading at DCS

Reading at DCS

4

0.2

0.2

8

39

39

12

78.4

78.4

16

119.6

119.6

20

159.04

159.04

Remark Status

1. Check RTD resistant OK

2. Inject mA at DCS OK

3. Check mA at converter card reading 3.5mA reading converter card

at output converter card low faulty.

Email ThisBlogThis!Share to XShare to Facebook
Posted in Generator | No comments
Newer Post Older Post Home

0 comments:

Post a Comment

Subscribe to: Post Comments (Atom)

Popular Posts

  • CCI Sulzer Valve and Drag Control Valve
    Description: PV6 CCI Part Number: 103.215.282.001 Valve Serial Number: Valve Control Description: Seal Set PV6 CCI Part Number: 000.101.000....
  • List of Hydro Power Plant in Malaysia
    Hydropower Peninsular Malaysia Tenaga Nasional Berhad operates three hydroelectric schemes in the peninsular with an installed generating ca...
  • Foxboro Malaysia
    Yesterday, I posted about the Foxboro Absolute Pressure Transmitter . Then searching around the internet for their support and services in M...
  • Sheet Metal
    Sheet metal is simply metal formed into thin and flat pieces. It is one of the fundamental forms used in metalworking, and can be cut and be...
  • SJ Gelugor Power Station
    Stesen Janakuasa Gelugor is owned by TNB. 
  • Hydroelectric in Malaysia
    Terengganu Hydroelectric Dam 400MW installed capacity Sultan Mahmud Power Station 4X100MW Cameron Highlands Dam 262MW installed capacity Jo...
  • Lumut or Segari Power Plant Photo
    Lumut or Segari Power Plant Perak View at Night Aerial view of Segari Power Plant and GB3 Combined Cycle Power Plant My last articles about ...
  • Langkawi Power Plant Teluk Ewa, Langkawi Kedah
    Langkawi Power Plant Teluk Ewa, Langkawi Kedah Langkawi Power Plant Teluk Ewa, Langkawi Kedah
  • Hydroelectricity Explained
    Hydroelectricity Itaipu Brazil/Paraguay Dam scene at night Close up view of dam: Itaipu Brazil/Paraguay Hydroelectricity dam Hydroelectric...
  • Sultan Iskandar Power Station
    Sultan Iskandar Power Station or Pasir Gudang  Power Station is located at Pasir Gudang  Johor.  Type of Plant Thermal (2 ST), combined cycl...

Categories

  • Analyser
  • Bently Nevada
  • Boiler
  • Car
  • Card
  • Coal and Ash
  • DCS
  • Electrical
  • Electro Chlorination Plant
  • Equipment
  • Events
  • Gauge
  • General
  • Generator
  • Heat Exchanger
  • Hydraulic
  • Hydroelectricity
  • Hydrolectricity
  • IT
  • Microrec
  • Mill
  • Miscellaneous
  • Motor
  • Package Equipment
  • PLC
  • Power Plant
  • Pump
  • Pump House
  • Samsung
  • Solar Energy
  • Summary Report
  • Switch
  • System
  • Terminal Block
  • Test Equipment
  • Testing and Commissioning
  • Tools
  • Toyota
  • Transducer
  • Transmitter
  • Turbine
  • Valve and Fitting
  • Water Treatment Plant

Blog Archive

  • ►  2014 (1)
    • ►  January (1)
  • ►  2013 (41)
    • ►  December (9)
    • ►  November (20)
    • ►  September (2)
    • ►  July (1)
    • ►  June (2)
    • ►  May (2)
    • ►  April (1)
    • ►  February (2)
    • ►  January (2)
  • ►  2012 (39)
    • ►  December (2)
    • ►  November (1)
    • ►  October (9)
    • ►  September (1)
    • ►  July (1)
    • ►  June (3)
    • ►  April (5)
    • ►  March (9)
    • ►  February (5)
    • ►  January (3)
  • ►  2011 (82)
    • ►  December (2)
    • ►  November (2)
    • ►  October (4)
    • ►  September (1)
    • ►  August (7)
    • ►  July (11)
    • ►  June (12)
    • ►  May (6)
    • ►  April (13)
    • ►  March (14)
    • ►  February (7)
    • ►  January (3)
  • ►  2010 (66)
    • ►  December (16)
    • ►  November (17)
    • ►  October (8)
    • ►  September (19)
    • ►  August (2)
    • ►  July (1)
    • ►  May (1)
    • ►  February (2)
  • ►  2009 (33)
    • ►  November (6)
    • ►  October (7)
    • ►  September (6)
    • ►  August (1)
    • ►  June (3)
    • ►  May (1)
    • ►  March (2)
    • ►  February (4)
    • ►  January (3)
  • ▼  2008 (182)
    • ►  December (1)
    • ►  November (2)
    • ►  October (7)
    • ►  September (11)
    • ►  August (26)
    • ►  July (6)
    • ►  June (7)
    • ►  May (9)
    • ►  April (21)
    • ►  March (43)
    • ►  February (22)
    • ▼  January (27)
      • Introduction to Generator Hydrogen Gas Cooling System
      • What is A Steam Turbine?
      • Lumut or Segari Power Plant
      • Unit No.1 LP Heater No.4 Normal Level Control Valv...
      • GP Joran Coal Fired Power Plant 2008 Among Staff U...
      • GP Joran Coal Fired Power Plant 2008
      • Band Screen Vega Radar Level Transmitter Trending
      • Conductivity Analyser High Alarm Operated at The G...
      • Change New Type Bandscreen Level Transmitter
      • Wet Coal Cause Bunker Level Transmitter Fluctuate
      • ECP Flow Switch Already Delivered Today
      • WTP ACID DAY TANK LEVEL MAGNETIC SWITCH FAULTY
      • Microrec Alarm Came Back
      • Washdown Water Sump Level Switch
      • New Project Flow Switch at Electrochlorination Plant
      • ABB Water Analyser Urgently Required
      • Bunker Level Transmitter Faulty
      • Fault Alarm at Microrec Appeared
      • Feed Water Tank Pressure Transmitter Bar Absolute
      • RTDs Converter
      • Unit No.3 Generator Stator Terminal Connection RTDs
      • Water Analyser QUZ Cabin
      • Waltron Sodium Analyser 9001 Series
      • Electrochlorination Plant (ECP) Flow Switch
      • Combustion Air Flow
      • How to Reboot Microrec
      • Manjung Coal Fired 3X700MW Power Plant
  • ►  2007 (2)
    • ►  December (1)
    • ►  November (1)
Powered by Blogger.

About Me

Unknown
View my complete profile