SEmax CAS40 is an ion-selective electrode system for the continuous measurement of ammonium and nitrate. The system consists of a sensor, electrodes and a transmitter (CAM40) with display and operating elements and is mounted on the basin rim. Up to two ion-selective sensors simultaneously measure the nitrate and ammonium in the activated sludge basin. It can be applied in: Wastewater treatment Municipal waste water Aeration basin for control of...
Thursday, 11 December 2008
Thursday, 20 November 2008
Levelflex M FMP45 - ABKASJB23A2A To Be Installed at HP Heater No.8
Posted on 07:51 by Unknown
Old Foxboro Level TransmitterLevelflex M FMP45 - ABKASJB23A2A To Be Installed at Hp Heater No.8Levelflex M FMP45 - ABKASJB23A2ALevel measurement, guided radar.High pressure/high temperature.Application: mainly liquids.Ideal to measure in bypass/chamber.Setup-/diagnostic software included.Factory precalibrated.Reliable measuring::: in case of moved surface + foam:: for changing mediasSIL declaration of conformityA Approval: Non-hazardous areaB Process...
Thursday, 13 November 2008
Ester Elektronik Digital Display Card Using at Generator Hydrogen Panel
Posted on 20:34 by Unknown
Item : Digital display Brand :Ester Elektronik Model : PMO 5405 S4 G2 Supply Voltage : 18 Vdc~ 30 Vdc Display height :14 mm red light.Power supply :230V /115 ACOuter dimension :96 x 48x120mm Item : Digital display Brand : Ester Elektronik Model : PMO-2160 N3 G3 I Supply Voltage : 18 Vdc~ 30 Vdc Power consumption : ~ 1.7 WType of Measurement: Channel 1 Counting forward and backward .Channel 2 for direction.Display : -19999 ….99999...
Wednesday, 29 October 2008
Pepperl fuchs digital card, potentiometer card and converter card at Hydrogen Gas Panel
Posted on 21:30 by Unknown
Pepperl fuchs digital card, potentiometer card and converter card at Hydrogen Gas PanelItem : Digital input card Brand : Pepperl fuchsModel : KFD2-SR2-EX1.W.LB Supply Voltage: 24 Vdc~ 30 Vdc Power consumption: ~ 1.7 W Ambient temp: 55 CWith 3 LED light : Red LED –PowerGreen LED- CHK: Yellow - Out Item : Potentiometer Card Brand : Pepperl fuchsModel : KFD2- PT2-Ex1-5Supply Voltage : 24 Vdc~ 30 Vdc Power consumption : ~ 1.7 WTerminal connection...
Friday, 24 October 2008
Electrostatic Precipitator ESP and Pre-Heater Blow Tanks Pressure Gauges
Posted on 21:14 by Unknown
List of WIKA Pressure Gauges:Items: Pressure gauge Bourdon tube pressure gauge, stainless steel seriesManufacturer: WikaModel: 232.50Measuring system: Stainless steelCase: Stainless steel with pressure vent Bezel ring: Cam ring (bayonet type), stainless steelAccuracy class: NS63: class 1.6; NS 100/160: class 1.0Nominal size: 100 mm Scale range: 0 kPa...400 kPaProcess connection: Diaphragm sealConnector position: Lower mountWindow: Laminated safety glassPointer: Standard blackwith integrated Alarm Contact, Electronic Sensor Series Model 830 Efirst...
Sunday, 19 October 2008
List of Instruments at SSC Hydraulics Power Packs
Posted on 10:03 by Unknown
List of Instruments at SSC Hydraulics Power Packs Items: Float switchManufacturer: FozmulaType: T/LL/70/9268HD Number: Z21049Electrical: Switching N/OFitting: Standard 1” BSP Items: Pressure GaugeManufacturer: T.J WilliamsType: 0-40Mpa 63mm ¼” bspHD Number: 016-81033-0 Items: Pressure SwitchManufacturer: TelemecaniqueType: XML-A160-D1S11HD Number: Z21049 Items: Pressure GaugeManufacturer: T.J WilliamsType: 0-15Mpa 63mm ¼” bspHD Number: Z21049 Items: Pressure SwitchManufacturer: TelemecaniqueType:...
Tuesday, 14 October 2008
Replacement of Level Transmitter mA Module for U3 Intermediate Bin
Posted on 20:13 by Unknown
The item for the replacements are as below:Item: Level Transmitter Guided level radarManufacturer: Endress + HauserModel: FMP40-AAA2GNJG21CA1Certificates: For non-hazardous areaProbe version, material: 4mm rope, predominantly bulk solids, 316Probe length: 7000 mm, 4mm rope, 316Sealing: Viton O-ringProcess connection & material: 1 ½” NPT, 316LElectronic insert/communication: 4-wire, 90…250VAC, 4-20mADisplay: With display VU 331 incl. on-site operationRemote electronic: Standard compact deviceHousing and cable gland/entry: Aluminium F12-housing,...
Monday, 13 October 2008
Air Quality Monitoring System (AQMS) - UPS System Battery
Posted on 22:15 by Unknown
Air Quality Monitoring System (AQMS) - UPS System BatteryItem: Rechargeable battery for UPSDescription: Valve regulated lead acid rechargable batteryManufacturer: YuasaModel: NP7-12 Rating: 12V 7.0AH Battery for the UPS System urgently required at the Air Quality Monitoring System....
Friday, 10 October 2008
WIKA Pressure Gauge 0-160 PSI - Liquid/ Glicerin Filled
Posted on 16:20 by Unknown
WIKA Pressure Gauge 0-160 PSI - Liquid/ Glicerin FilledSpecifications: Pressure Range: 0-160 PSISize: 2" (50mm)Connection: 1/4" NPT center back mountAccuracy: +/- 2/1/2% of spanWetted Parts: Copper AlloyCase: 304 Stainless SteelWindow: Polycarbonate, Buna-N gasketCase-to-Socket: Viton O-ringDial: White ABS plasticPointer: Black aluminumDial Layout: Numbers every 20 PSI, tick marks every 2 PSIMedia Temperature: 140º F maximumAmbient Temperature:...
Thursday, 9 October 2008
VEGAPULS68 for Bunker Level and VEGAPULS62 For Bandscreen
Posted on 19:42 by Unknown
This is the latest 2 pieces or types new Vega Radar Level Transmitter to be check their performance since installed at our power plant. For those still blur, you can view and check what kind of these level transmitter at the related articles at the end of this post. Your comments or any shared value are welcome. VEGAPULS68 for Bunker Level Approval: ATEX II 1/2G,2G Eexd ia T5Version/material: with horn antenna 316LProcess fitting: Process fitting/material:suit to the original diameter.Electronics: four wire 4…20mA HARTHousing: aluminium double...
Thursday, 18 September 2008
H2 Purity Gas Analyzer to be Purchase
Posted on 18:16 by Unknown
Specifications of spare parts for ABB Hydrogen Purity System with redundancy: P/N : 6548-001Manufacturer : ABB Automation, UK Replacement Hydrogen Purity and Purge Gas katharometer with redundancy, calibrated for 3 ranges of: 85 – 100% H2 in Air, 0 – 100% Air in CO2 and 0 – 100% H2 in CO2 Output : 0 – 10mV Power Supply : 350mA Zero Gas : 85% H2 in 15% Air Note : Replacement for Serial No G846802 P/N ...
Tuesday, 16 September 2008
ASCO Solenoid Valve New Ordering
Posted on 17:46 by Unknown
ITEM : ASCO SOLENOID VALVE SV CUB20MANUFACTURER: ASCOMODEL: SCE210D001110 VAC, 50 HZSTAINLESS STEELCONNECTION SIZE : 3/8" ITEM: ASCO AC KIT FOR SOLENOID VALVEMANUFACTURER: ASCOPART NO: SCE210D3N5MIB AC KIT: C302279 ITEM: ASCO AC KIT FOR SOLENOID VALVEMANUFACTURER: ASCOPART NO: SCE210D022N5MIBAC KIT: C302284 ITEM: ASCO AC KIT FOR SOLENOID VALVEMANUFACTURER: ASCOPART NO: SCE210D001N5MIBAC KIT: C302273 ITEM: ASCO SOLENOID VALVEBRAND: ASCO JOUCOMATICMODEL NO: G551A017MSBODY: BLACK ANODIZIEDMAX INLET PRESS:...
Sunday, 14 September 2008
Fisher Valve Link Software and Fisher Hart Modem Model: Maxteck Viator (USB)
Posted on 17:20 by Unknown
Fisher Valve Link SoftwareModel: VL2005 (LITE)Communication: HartInitial Tags Limit: 5Fisher Hart Modem Model: Maxteck Viator (USB)This communicator is going to be delivered at our power plant a few days. Originally used for communicating between laptop and Fisher Valve 585C via the valve link software. I will update more later.Related articles:Fisher valve control type 585C servicingFisher Air Filter Regulator 67CFR-...
Thursday, 11 September 2008
Fisher Control Valve Type 585C Servicing Report Updated
Posted on 23:48 by Unknown
What type of servicing did this Fisher guys to the Fisher Valve?Collect the machining coupling from the machine shopRemove actuatorInstall new actuator on the valveSet the tubing and fittingsValve calibration Mount the volume tank near to the wall supportPerform calibration and fine tuning on the volume boosterResult satisfactory. Stroking speed up to 2 secondsThis is the thing they puton their report. Looks weired.... Mmm... Anyway, the valve can operate smooth...
Wednesday, 10 September 2008
Row of Turbine or Generator
Posted on 00:53 by Unknown
Row of Turbine at in Turbine Hall Power StationMaybe the pic (turbine) at the back of this unit not so clear... Sor...
Saturday, 6 September 2008
ABB TZID and TZIDC Project
Posted on 23:30 by Unknown
Now we have some project improvement to the plant equipment. This time we are going to change some valve positioner to the ABB TZID positioner. Before this, we have the trial unit and the result is satisfied. For the starting, the list below is a part of the ABB project.1) LP Bypass TZID-C (Single acting, fail safe) Positioner 4-20mA Feedback signalInstallation:Mounting bracket suitable for the blackborough valveInstallation materialFitting and tubings copper material2) Feedwater Regulator TZID-C (single acting, fail safe) Positioner...
Friday, 5 September 2008
Accu-Gage Pencil Tire Pressure Gauge
Posted on 21:24 by Unknown
Accu-Gage Pencil Tire Pressure GaugeDurable stainless steel construction Easy-to-read, four-sided nylon scale, 2 psi units 0-60 psi ra...
Thursday, 4 September 2008
Cerabar S PMP75 - E+H Level Transmitter Installation
Posted on 23:23 by Unknown
Remember 2 days ago I post about this Endress Hauser Level Sensor Transmitter Cerabar S PMP75? Remember the about the Druck 1830 level sensor transmitter I posted few months ago?Cerabar S PMP75 - E+H Level Transmitter Installation WorkCerabar S PMP75 - E+H Level Transmitter Installation WorkHope you enjoy this entry and and don't forget to come back later. Any comments and suggestions are welco...
Wednesday, 3 September 2008
Monday, 1 September 2008
Cerabar S PMP75 - PMP75-ABA1HB8B3AAA CERABAR S DIGITAL PRESSURE TRANSMITTER
Posted on 23:12 by Unknown
Cerabar S PMP75 Cerabar S with metallic measuring diaphragm and diaphragm seal. Overload-resistant and function-monitored. Communication via HART, PROFIBUS PA or FOUNDATION Fieldbus.Areas of applicationThe Cerabar S pressure transmitter is used for the following measuring tasks: Absolute pressure and gauge pressure in gases, steams or liquids in all areas of process engineering and process measurement technology Level,...
CruzTOOLS TirePro™ Digital Tire Pressure Gauge
Posted on 21:21 by Unknown
CruzTOOLS TirePro™ Digital Tire Pressure GaugeCompact ergonomic shape for easy pressure readings Large display, with readings in 1/10 psi increments Readings available in multiple scales: psi; BAR, Kpa and Kg-cm Auto power off, with last-reading recall feat...
Sunday, 31 August 2008
ABB Advant Controller 31 Analog I/O Card Failure
Posted on 03:01 by Unknown
ABB Advant Controller 31 Analog I/O 07AC91 CardABB Advant Controller 31 Analog I/O Card failure and effect all the Generator System. Currently problem solved by replace the faulty module 07AC91 and unit returned back in good conditi...
Saturday, 30 August 2008
Accu-Gage 11" Dial Tire Pressure Gauges
Posted on 21:15 by Unknown
Accu-Gage 11" Dial Tire Pressure GaugeFlexible 11” hose between gauge and chuck for hard-to-reach tire valves Dual range scales with psi and kPa or kg/cm are available Polished brass bezel, stem and pressure release valve assembly holds pressure reading until released Push button valve bleeds air to desired pressure 0-60 psi ra...
Thursday, 28 August 2008
Bike Tyre Pressure Gauge
Posted on 21:15 by Unknown

Bike Tyre Pressure GaugeThis unique pressure gauge used Digital Valve Cap - a cap with a digital readout of the current tire pressure. It’s powered by a small cell battery and activated when you press the c...
Turbine Drain Sump Pit - Upgrading Level Probe Switch to Ultrasonic Switch Type
Posted on 20:52 by Unknown
Project in Progress - Turbine Drain Sump Pit - Upgrading Level Probe Switch to Ultrasonic Switch TypeThe previous level probe switch always giving fault signal and disturbs controlling of the water level in the system. The new type of Ultrasonic Model non-contact which expected to be more robust and reliable. Specifications:FDU91F-RN1A* PROSONIC S FMU90-R11CA131AA1A* PROSONIC S RSG30-A1A1AAA1* ECOGRAGH TNow it is almost comple...
Wednesday, 27 August 2008
PPC4 Pressure controller/calibrator
Posted on 20:47 by Unknown

DH Instruments, a Fluke company announce the PPC4 Pressure controller/calibrator; a high performance instrument designed to provide versatility and ease of use in calibration labs and manufacturing environments. The PPC4 covers the absolute range of 1 kPa (0.15 psi) to 10 MPa (1500 psi) and gauge equivalent including very low differential pressures. PPC4’s emphasis is on high end performance, minimizing measurement uncertainty and maximizing...
WIKA Liquid Filled Pressure Gauge 0-160 PSI 213.53
Posted on 17:12 by Unknown
WIKA Pressure Gauge 0 to 160 PSIThe specifications are as below: Pressure Gauge Range: 0-160 PSI/Bar dual scaleSize: 2" (50mm)Connection: 1/4" NPT center back mountAccuracy: +/- 2/1/2% of spanWetted Parts: Copper AlloyCase: 304 Stainless SteelWindow: Polycarbonate, Buna-N gasketCase-to-Socket: Viton O-ringDial: White ABS plasticPointer: Black aluminumDial Layout: Numbers every 20 PSI, tick marks every 2 PSIMedia Temperature: 140º F maximumAmbient...
Tuesday, 26 August 2008
Ross Liquid Filled Pressure Gauge 0-7 kg/cm2 ~ 100psi
Posted on 23:47 by Unknown
Ross Liquid Filled Pressure Gauge 0-7 kg/cm2 ~ 100psiSpecifications:Pressure Gauge Manufacturer RossRange: 0-7 kg/cm2 ~ 100psi Liquid FilledDial Gauge: 63mmDirect Bottom Mount...
Fisher Control Valve Type 585C Servicing
Posted on 23:33 by Unknown
Fisher Control Valve Type 585C ServicingFisher Air Filter Regulator Today, Fisher Control Valve vendor doing their valve servicing at our power pla...
Wika Pressure Gauge At Hydrogen Pressure Control Valve
Posted on 17:40 by Unknown

WIKA Pressure Gauge 0-60bars and 0-15barsUsed At The Hydrogen Pressure Control Va...
Sunday, 24 August 2008
Kelco F25-B Series Corrosive Flow Switch
Posted on 17:34 by Unknown
Kelco F25-B Series Corrosive Flow SwitchThis is a new flow switch that we found at market and currently installed at our electrolyser ECP Stream. Alternative to Flotech ECP Flow Switch which give a lot of problems recently.Anyway, just for your information this kind of switch already used 3 months and the result is very good and no defect from operation at all so far. If this F25-B Series Corrosive Flow Switch can be long lasting live, I would consider...
Friday, 22 August 2008
Hydrogen Sensor - RKI Instrument
Posted on 09:07 by Unknown
RKI Instrument Hydrogen Sensor Features Explosion proof housing and sensor design H2 specific solid state sensor for 0 - 2000 ppm H2 specific catalytic sensor for 0 - 100%LEL Molecular sieve filter built in; highly specific to H2 Eliminates false alarms from IPA and other gases 4-20 mA transmitter, 24VDC Applications Semiconductor...
Wednesday, 20 August 2008
WEKA Visual Level Indicator VLI
Posted on 01:49 by Unknown
WEKA Visual Level Indicator VLIWEKA Visual Level Indicator VLIWEKA Visual Level Indicator VLI operating principle is based on the use of a permanent bar magnet system which ensures the safe and reliable activation of visual indication elements (flags), swithes, and transmitters, even when used on thick-wall high pressure indicator pipe.This is what we have in our power plant which currently need to be replaced because of the britles. Then we have...
Saturday, 16 August 2008
Crowcon Hydrogen Leakage Detector Monitoring System - Flamgard Exe
Posted on 19:57 by Unknown
Crowcon Hydrogen Sensor - 96HDCrowcon Hydrogen Panel RackCrowcon Hydrogen Panel DisplayCrowcon Hydrogen Panel (Back) Hydrogen is highly explosive gas. All of the 7 Hydrogen detectors in our Electro Chlorination Plant (ECP) are using Crowcon Hydrogen monitoring system. A situation lead to an extremely dangerous explosive condition if one of the ECP streams were to develop a leak and Hydrogen concentration in the building reached above the Lower...
Endress+Hauser Electromagnetic Flowmeter Promag 53 Project Update
Posted on 02:37 by Unknown
Promag 53 TransmitterPromag 53 Recorder and TransmitterPromag 53 Transmitter Sensor LocationPromag 53 Sensor at the ECP PipePromag 53 RecorderYesterday I post about the Endress+Hauser Electromagnetic Flowmeter Promag 53 Project. Now the project still in testing for around 2 weeks. If this success, we will try to install this new model to our Electro Chlorination Pla...
Thursday, 14 August 2008
Endress+Hauser Electromagnetic Flowmeter Promag 53
Posted on 17:48 by Unknown
Endress+Hauser Electromagnetic Flowmeter Promag 53This is a new electromagnetic flowmeter delivered yesterday by Endress+Hauser personal and will be installed at the electrolyser chlorination plant pipe for flow measurement. The consequences of flow switch failure frequently and repeated recently at this electrolyser pipe which cause the Electro Chlorination Plant trip.This situasion leads to several trial units of many brands to avoid this happen...
Wednesday, 13 August 2008
PIKOM PC Fair August 2008
Posted on 18:46 by Unknown
14 - 16 August 2008 11:00 am - 9:00 pm KB Mall, Kota Bharu, Kelantan Jalan Hamzah, 15050 Kota Bharu Pusat Dagangan Terengganu, Kuala Terengganu, Terengganu Padang Hiliran, 21100 Kuala Terengganu Star Parade, Alor Star, Kedah Jalan Teluk Wanjah, 05200 Alor Star ...
Vegapuls 62 Radar Level Trasmitter - Warranty Claim Done
Posted on 17:24 by Unknown
Vegapuls 62 Radar Level Trasmitter 3 months delivered after send to Vega for warranty claim. This time is different cause from the previous one. Ready to install by today.Related articles:- Bandscreen Vega Radar Type Trending- New Type of Bandscreen Level Transmitter...
Monday, 11 August 2008
CCI Sulzer Valve and Drag Control Valve
Posted on 17:34 by Unknown
Description: PV6CCI Part Number: 103.215.282.001Valve Serial Number: Valve ControlDescription: Seal Set PV6CCI Part Number: 000.101.000.783Valve Serial Number: Valve Control Description: SSB10-24VDC CCI Part Number: 103.203.368.210 Valve Serial Number: Safety Unit Description: SSB10-24VDC CCI Part Number: 103.203.368.210 Valve Serial Number: Safety Unit Description: Seal Set SSB10-24VDC CCI Part Number: 103.203.368.290 Valve Serial...
Sunday, 10 August 2008
Conductivity Analyser at the Condenser Hotwell
Posted on 20:06 by Unknown
ABB Conductivity Analyser TransmitterThis photo showing the Transmitter of Conductivity Analyser at the Condenser Hotwell. Conductivity purpose at the Condenser Hotwell are as below: • It is the cheapest and the most reliable type of analyzer which serve many function • To detect seawater ingress. Water conductivity will increase if there is seawater ingress. • To monitor condensate and feed water quality. Water conductivity will...
Bourdon Haenni 0-6 Bar Pressure Gauge
Posted on 00:47 by Unknown
Pressure Gauge Manufacturer: Bourdon HaenniPart Number: EN 837-1 Type: Lower Direct Mounting Range: 0-6 Bar Dial gauge: 100mm Connection: 1/4" ...
Friday, 8 August 2008
Sample Convertion of Pressure
Posted on 04:03 by Unknown

Sample Convertion of PressureExample reading: 1 Pa = 1 N/m2 = 10−5 bar = 10.197×10−6 at = 9.8692×10−6 atm, etc....
Subscribe to:
Posts (Atom)